BXGKY - GRAY GLOSS AIR DRY ENAMEL, X-1671

  • MSDS: BXGKY
  • Manufacturer: SENTRY PAINT CO
  • Product Name: GRAY GLOSS AIR DRY ENAMEL, X-1671
  • National Stock Number: 8010-00N059042
Product Identification

Product ID:GRAY GLOSS AIR DRY ENAMEL, X-1671
MSDS Date:12/22/1992
FSC:8010
NIIN:00N059042
MSDS Number: BXGKY

Responsible Party
SENTRY PAINT CO
MILLER & LAWRENCE DR
DARBY, PA 19023
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 215-522-1900

Cage: IO235

Contractor
SENTRY PAINT CO
DARBY, PA 19023 US

Telephone: 215-522-1900

Cage: IO235

Ingredients

SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (RULE 66

CAS: 64742-88-7

Fraction By Weight: 39.8%

OSHA PEL 500 (MFR)

ACGIH TLV: 100 (MFR)


CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE

RTECS: 9999999ZZ


SEWERS, STREAMS, AND GROUNDWATER WITH SPILLED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: IRRITATION, REDNESS,
TEARING, BLURRED VISION. SKIN: DRYNESS, IRRITATION, DERMATITIS.
INHAL: NASAL AND RESPIRATORY IRRITATION, DIZZINESS, WEAKNESS,
NAUSEA, HEADACHE. INGEST: NAUSEA, VOMITI NG, DIARRHEA.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:ASPIRATION OF MATERIAL INTO THE
LUNGS CAN CAUSE CHEMICAL PNEUMONITIS.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG HAS STOPPED, GIVE
ARTF RESP, KEEP WARM & QUIET. GET MED ATTN IMMED. EYE:FLUSH W/LRG
AMTS OF H*2O, LIFTING UPPER & LOWER LIDS OCCASNLY. CONTINUE FOR AT
LEAST 1 5 MIN. GET MED ATTN. SKIN:THORO WASH EXPOSED AREA W/SOAP &
H*2O. REMOVE CONTAMD CLTHG. INHAL:DO NOT INDUCE VOMIT, KEEP PERSON
WARM, QUIET & GET MED ATTN. ASPIR OF MATL INTO LUNGS DUE TO VOMIT
(ING 2)

Fire Fighting

Flash Point Method:CC
Flash Point:107F,42C
Lower Limits:0.08
Extinguishing Media:CO*2/DRY CHEMS FOR SMALL FIRES. FOAM FOR LRG FIRES.
COOL CLOSED CONATINERS WITH WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:OSHA CLASS II. CLOSED CNTNS MAY BUILD
EXPLOS PRESS FROM HEAT. VAPS ARE HVR/(SUPDAT)

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIM ALL IGNIT SOURCES
(FLAMES, HOT SURFACE, & SOURCES OF ELEC, STATIC/FRICTIONAL SPARKS).
DIKE & CNTN SPILL W/INERT MATL SUCH AS SAND/EARTH. TRANSFER LIQS TO
COVERED METAL CNTNR S FOR RECOVERY/DISP. PREVENT CONTAM OF (ING 3)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:INCINERATE ONLY IN EPA PERMITTED
FACILITY. DO NOT INCINERATE CLOSE CONTAINERS.
Other Precautions:NOT IT IS THE USERS OBLIGATION TO DETERMINE
CONDITIONS OF SAFE USE OF THIS PRODUCT.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA SELF CONTAINED BREATHING
APPARATUS WHERE CONCENTRATIONS MAY BE ABOVE TLV LIMITS. BELOW TLV
LIMITS, USE A NIOSH/MSHA APPROVED VAPOR RESPIRATOR.
Ventilation:LOCAL EXHAUST MUST BE SUFFICIENT TO KEEP AIRBORNE VAPOR
CONCENTRATION BELOW THE TLV LIMIT.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EYE BATH AND SAFETY SHOWER. TO PREVENT
REPEATED OR PROLONGED SKIN CONTACT, WEAR IMPERVIOUS CLOTHING AND
BOOTS.
Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE RE-USED.
Supplemental Safety and Health
FIRE EXPLO HAZ:AIR & MAY TRAVEL ALONG GROUND/MAY BE MOVED BY VENT &
IGNITED BY PILOT LIGHTS, OTHER FLAMES, SPARKS, HEATERS, SMKNG,
ELECTRIC MOTORS, STATIC DISCHARGE/IGNIT SOURCES AT LOCATIONS
DISTANT FROM MATL HNDLG POINT. NEVER USE WELDING/CUTTING TORCH
ON/NEAR DRUM (EVEN EMPTY) BECAUSE PROD/RESIDUE CAN IGNITE EXPLO.

Chemical Properties

Boiling Pt:B.P. Text:>300F,>149C
Vapor Pres:SEE ING 1
Vapor Density:HVR/AIR
Spec Gravity:1.126
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:GRAY PAINT

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESS HEAT, SPARKS, AND OPEN FLAME.
Hazardous Decomposition Products:FUMES MAY CONTAIN THE HAZARDOUS
MATERIALS.

Disposal

Waste Disposal Methods:DISPOSAL IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL LAWS. INCIN ONLY IN EPA PERMITTED FACILITY. DO NOT INCINERATE
CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their